HiPNUC | SKU:
HiPNUC HI14R Sensor
Regular price
$270.00
Unit price
HiPNUC HI14R Sensor - HI14R2 / URT / 010 is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
- We automatically select the most cost-effective carrier from China for each destination country
- Shipping rates are dynamically calculated based on real-time quotes
- Final rates may vary due to promotional offers or carrier adjustments
HiPNUC HI14R Sensor - HI14R2 / URT / 010 is backordered and will ship as soon as it is back in stock.
Product Information
Application Scenarios
Humanoid Robots
Robotic Arms
Exoskeletons
Quadruped Robots
AGV Vehicles
ARU Robots
Technical Specifications
| Parameter | Value |
|---|---|
| Gyroscope Specifications: | |
| Gyroscope Measurement Range | ±250 / ±500 / ±1000 / ±2000 °/s (Default: ±2000 °/s) |
| Gyroscope Resolution | 16 bit |
| Gyroscope Scale Factor Error | HI14‑R2/R3: Typ <600 ppm, Max 850 ppm HI14‑R5: Typ <400 ppm, Max 600 ppm (RMS, @100 °/s) |
| Gyroscope Nonlinearity | ±0.05 %FS |
| Gyroscope Noise Density (47 Hz Bandwidth) | HI14‑R2/R3: 0.008 °/s/√Hz HI14‑R5: 0.005 °/s/√Hz |
| Gyroscope 3dB Bandwidth | 80~200 Hz |
| Gyroscope Zero Rate Output | ±0.1~±0.2 °/s (RMS) |
| Gyroscope Sampling Rate | 1000 Hz |
| Gyroscope Bias Instability (1σ Typ / 3σ Max) | HI14‑R2/R3: X=1.5/2.5 °/h, Y=1.9/3.2 °/h, Z=1.7/3.2 °/h HI14‑R5: X=1.1/1.5 °/h, Y=1.4/2.0 °/h, Z=1.2/2.0 °/h |
| Gyroscope Short-term Bias Stability (10s Averaging) | HI14‑R2/R3: X=5.5/7.0 °/h, Y=7.5/9.0 °/h, Z=5.5/7.0 °/h HI14‑R5: X=3.9/5.0 °/h, Y=5.3/6.5 °/h, Z=3.9/5.0 °/h |
| Gyroscope Bias Repeatability | HI14‑R2/R3: X=11.5/21.0 °/h, Y=15.0/30.0 °/h, Z=9.5/15.0 °/h HI14‑R5: X=8.0/15.0 °/h, Y=11.0/18.0 °/h, Z=7.0/11.0 °/h |
| Gyroscope Angle Random Walk | HI14‑R2/R3: X=0.30/0.60 °/√h, Y=0.40/0.70 °/√h, Z=0.20/0.40 °/√h HI14‑R5: X=0.22/0.45 °/√h, Y=0.25/0.50 °/√h, Z=0.15/0.30 °/√h |
| Gyroscope Full Temperature Bias Drift (-40℃~85℃) | 0.07~0.15 °/s |
| Gyroscope G‑Sensitivity | 0.05 °/s/g (X/Y/Z Axis) |
| Accelerometer Specifications: | |
| Accelerometer Measurement Range | ±3 / ±6 / ±12 / ±24 g (Default: ±12 g) |
| Accelerometer Resolution | 16 bit |
| Accelerometer Initial Zero Bias | 1~2 mg (RMS) |
| Accelerometer Nonlinearity | ±0.01 %FS |
| Accelerometer Noise Density | HI14‑R2/R3: 0.10~0.12 mg/√Hz HI14‑R5: 0.072~0.085 mg/√Hz |
| Accelerometer 3dB Bandwidth | 90~200 Hz |
| Accelerometer Sampling Rate | 1000 Hz |
| Accelerometer Bias Instability | HI14‑R2/R3: X=0.015/0.020 mg, Y=0.020/0.045 mg, Z=0.015/0.020 mg HI14‑R5: X=0.010/0.014 mg, Y=0.014/0.016 mg, Z=0.011/0.015 mg |
| Accelerometer Short-term Bias Stability (10s Averaging) | HI14‑R2/R3: X=0.06/0.10 mg, Y=0.055/0.150 mg, Z=0.05/0.06 mg HI14‑R5: X=0.04/0.07 mg, Y=0.04/0.11 mg, Z=0.035/0.045 mg |
| Accelerometer Bias Repeatability | HI14‑R2/R3: X=0.127/0.250 mg, Y=0.090/0.150 mg, Z=0.070/0.150 mg HI14‑R5: X=0.08/0.15 mg, Y=0.06/0.10 mg, Z=0.05/0.09 mg |
| Accelerometer Velocity Random Walk | HI14‑R2/R3: 0.055~0.065 m/s/√h HI14‑R5: 0.040~0.046 m/s/√h |
| Accelerometer Full Temperature Bias Drift (-40℃~85℃) | 2~5 mg (X/Y/Z Axis) |
| Magnetometer & Temperature Specifications: | |
| Magnetometer Measurement Range | ±2000 μT |
| Magnetometer Noise | 0.19~0.45 μT |
| Magnetometer Nonlinearity | ±10~±20 μT |
| Temperature Sensor Range | -40℃~85℃ |
| Temperature Sensor Offset Error | ±5 ℃ |
| Attitude & Accuracy Specifications: | |
| Static Pitch & Roll Accuracy | 0.15~0.20 ° |
| Dynamic Pitch & Roll Accuracy | 0.20~0.30 ° |
| AHRS Heading Accuracy | 2~3 ° |
| Static Heading Drift (6DoF, 2h Static) | 0.15~0.20 ° |
| Dynamic Heading Drift | ±5 ° (HI14‑RX) |
| Heading Rotation Error (@100 °/s, 6DoF) | HI14‑R2/R3: 0.20~0.30 ° HI14‑R5: 0.15~0.20 ° |