Xike Sensor
Sold out

Xike XK895V Sensor

Regular price $780.00

Version
Communication
Range

Delivery and Shipping

  • We automatically select the most cost-effective carrier from China for each destination country
  • Shipping rates are dynamically calculated based on real-time quotes
  • Final rates may vary due to promotional offers or carrier adjustments

Product Information


Application Scenarios

Humanoid Robots
Robotic Arms
Exoskeletons
Quadruped Robots
AGV Vehicles
ARU Robots

Technical Specifications

Parameter Value
Model XK890V XK895V
Operating Temperature Range -40°C ~ +85°C -40°C ~ +85°C
Storage Temperature Range -55°C ~ +125°C -55°C ~ +125°C
Connector Lead wire (1.5 m) or waterproof aviation socket (custom) Lead wire (1.5 m) or waterproof aviation socket (custom)
Protection Class IP67 (IP68 customizable) IP67 (IP68 customizable)
Housing Material Aluminum alloy, sandblasted anodized Aluminum alloy, sandblasted anodized
Mounting Four M4 screws Four M4 screws
Cable 1.5 m, wear‑resistant, oil‑resistant, wide‑temperature, shielded 6×0.2 mm² 1.5 m, wear‑resistant, oil‑resistant, wide‑temperature, shielded 6×0.2 mm²
Weight (excluding packaging) 350 g 350 g
Supply Voltage 9~35 V (12/24 V typical) 9~35 V (12/24 V typical)
Operating Current 45 mA 45 mA
Output Load (Resistive) 15 Ω (typical) 15 Ω (typical)
Output Load (Capacitive) 18 nF (typical) 18 nF (typical)
Measurement Range ±30° ±30°
Measurement Axes Y‑axis optional X‑axis / XY‑axis
Zero Temperature Coefficient ±0.0005/°C (-40 to +85°C) ±0.0005/°C (-40 to +85°C)
Sensitivity Temperature Coefficient ≤100 ppm/°C (-40 to +85°C) ≤100 ppm/°C (-40 to +85°C)
Frequency Response DC response, 100 Hz DC response, 100 Hz
Resolution 0.0005° 0.0005°
Accuracy 0.001° (-40 to +85°C) 0.001° (-40 to +85°C)
Long‑term Stability <0.0016° (-40 to +85°C) <0.0016° (-40 to +85°C)
Power‑on Startup Time 0.15 s 0.15 s
Response Time 0.01 s 0.01 s
0° Output 0‑5V: -2.5V; 0‑10V: -5V 0‑5V: -2.5V; 0‑10V: -5V
Output Signal 0‑5V / 0‑10V optional, RS232 (default) / RS485 optional 0‑5V / 0‑10V optional, RS232 (default) / RS485 optional
Mean Operating Time ≥45,000 hours ≥45,000 hours
Shock Resistance 20000 g, 0.5 ms, 3 times/axis 20000 g, 0.5 ms, 3 times/axis
Vibration Resistance 10 grms, 10~1000 Hz 10 grms, 10~1000 Hz
Insulation Resistance ≥100 MΩ ≥100 MΩ